Prosthetic Over Post
Zirocnia Glass Fiber Post
Prosthetic Over Post are glass fiber posts with conical-cylindrical shape.
As Overfibers post surfaces are particularly rough the silanization treatments are an optional.
Clinical Directions
Prosthetic Over Post are specific for teeth with missing or massively destroyed crowns as they present the maximum emergency diameter at the level where they come out of the root, according to the most recent studies regarding the root canal shapes of the teeth treated endodontically.
Their special quality is having a large emergency coronal diameter compared to the relatively small apical diameter: this design stabilizes the prosthetic core much more effectively, making the restoration more resistant to the displacing forces of mastication.
Code: SKPOP0 (0-1-2)
Content:
- 3 Unit – Prosthetic Over Post # 0
- 3 Unit – Prosthetic Over Post # 1
- 3 Unit – Prosthetic Over Post # 2
- 1 Prosthetic Drill # 0
- 1 Prosthetic Drill # 1
- 1 Prosthetic Drill # 2
Code: SKPOP1 (1-2-3)
Content:
- 3 Unit – Prosthetic Over Post # 1
- 3 Unit – Prosthetic Over Post # 2
- 3 Unit – Prosthetic Over Post # 3
- 1 Prosthetic Drill # 1
- 1 Prosthetic Drill # 2
- 1 Prosthetic Drill # 3
Code: POP100
Content: 10 Unit – Prosthetic Over Post # 0
Code: POP101
Content: 10 Unit – Prosthetic Over Post # 1
Code: POP102
Content: 10 Unit – Prosthetic Over Post # 2
Code: POP103
Content: 10 Unit – Prosthetic Over Post # 3
Code: POP104
Content: 10 Unit – Prosthetic Over Post # 4
Code: PD100
Content: 1 Prosthetic Drill # 0
Code: PD101
Content: 1 Prosthetic Drill # 1
Code: PD102
Content: 1 Prosthetic Drill # 2
Code: PD103
Content: 1 Prosthetic Drill # 3
Code: PD104
Content: 1 Prosthetic Drill # 4
Features | Advantages |
Highly retentive surface | Increases the post / cement adhesion without weakening it with deep grooves |
Zirconia glass fiber 80% | high flexure strength 1500 MPa |
Balanced flexure E-modulus | 60 GPa to better stabilize the restoration |
Translucent | to accelerate the activation of dual cements |
Radiopacity | 3.0 mm or 300% Al equivalent |
Fatigue Strength | 5 Millions Cycles Without Breaking |
Sterilization in autoclave | 135°C at 2.1 bar for 5 min without any variation of their resistance |
Prosthetic Over Post and Prosthetic Drill are available in five sizes, with color coding for a corresponding use.
Color | Code | Maximum diameter | Point diameter | Root part conicity (%) | Total length | Drill |
---|---|---|---|---|---|---|
POP100 | 1.20 | 0.70 | 0.04 | 19 | PD100 | |
POP101 | 1.40 | 0.80 | 0.05 | 19 | PD101 | |
POP102 | 1.60 | 0.80 | 0.066 | 19 | PD102 | |
POP103 | 1.80 | 0.90 | 0.08 | 19 | PD103 | |
POP104 | 2.10 | 1.10 | 0.08 | 19 | PD104 |
- Fiber Post Bonding Using Self-Etching and Resin Cements
S. PALLOTTINI, A. LLUKACEJ, C. MONACO, and P. BALDISSARA, University of Bologna, Bologna, Italy - Fiber Post Removal: Comparative Study Using a New Post Concept
P. BALDISSARA1, D. MELILLI2, L. CIOCCA1, and L.F. VALANDRO3, 1University of Bologna, Bologna, Italy, 2University of Palermo, Palermo, Italy, 3Federal University of Santa Maria, Santa Maria, Brazil - Effect of Sterilization on Fiber Posts Fracture Strength
G. IORIZZO, S. BETAZZONI, L. CIOCCA, and P. BALDISSARA, University of Bologna, Bologna, Italy - Microtensile bond strength of fiber post: effect of surface roughness
P. BALDISSARA1*, C. MONACO1, L.F. VALANDRO2, University of Bologna, Bologna, Italy1 and Federal University of Santa Maria, Brazil2