Prosthetic Over Post

Zirocnia Glass Fiber Post

Prosthetic Over Post are glass fiber posts with conical-cylindrical shape.
As Overfibers post surfaces are particularly rough the silanization treatments are an optional.

Clinical Directions

Prosthetic Over Post are specific for teeth with missing or massively destroyed crowns as they present the maximum emergency diameter at the level where they come out of the root, according to the most recent studies regarding the root canal shapes of the teeth treated endodontically.

Their special quality is having a large emergency coronal diameter compared to the relatively small apical diameter: this design stabilizes the prosthetic core much more effectively, making the restoration more resistant to the displacing forces of mastication.

More information

Code: SKPOP0 (0-1-2)
Content:

  • 3 Unit – Prosthetic Over Post # 0
  • 3 Unit – Prosthetic Over Post # 1
  • 3 Unit – Prosthetic Over Post # 2
  • 1 Prosthetic Drill # 0
  • 1 Prosthetic Drill # 1
  • 1 Prosthetic Drill # 2

Code: SKPOP1 (1-2-3)
Content:

  • 3 Unit – Prosthetic Over Post # 1
  • 3 Unit – Prosthetic Over Post # 2
  • 3 Unit – Prosthetic Over Post # 3
  • 1 Prosthetic Drill # 1
  • 1 Prosthetic Drill # 2
  • 1 Prosthetic Drill # 3

Code: POP100
Content: 10 Unit – Prosthetic Over Post # 0

Code: POP101
Content: 10 Unit – Prosthetic Over Post # 1

Code: POP102
Content: 10 Unit – Prosthetic Over Post # 2

Code: POP103
Content: 10 Unit – Prosthetic Over Post # 3

Code: POP104
Content: 10 Unit – Prosthetic Over Post # 4

Code: PD100
Content: 1 Prosthetic Drill # 0

Code: PD101
Content: 1 Prosthetic Drill # 1

Code: PD102
Content: 1 Prosthetic Drill # 2

Code: PD103
Content: 1 Prosthetic Drill # 3

Code: PD104
Content: 1 Prosthetic Drill # 4

Features Advantages
Highly retentive surface Increases the post / cement adhesion without weakening it with deep grooves
Zirconia glass fiber 80% high flexure strength 1500 MPa
Balanced flexure E-modulus 60 GPa to better stabilize the restoration
Translucent to accelerate the activation of dual cements
Radiopacity 3.0 mm or 300% Al equivalent
Fatigue Strength 5 Millions Cycles Without Breaking
Sterilization in autoclave 135°C at 2.1 bar for 5 min without any variation of their resistance

Prosthetic Over Post and Prosthetic Drill are available in five sizes, with color coding for a corresponding use.

Color Code Maximum diameter Point diameter Root part conicity (%) Total length Drill
POP100 1.20 0.70 0.04 19 PD100
POP101 1.40 0.80 0.05 19 PD101
POP102 1.60 0.80 0.066 19 PD102
POP103 1.80 0.90 0.08 19 PD103
POP104 2.10 1.10 0.08 19 PD104